Imedos systems ug, jena, germany is a commercially available system which is composed of a fundus camera, video camera, realtime monitor, and a personal. Several studies, using instruments able to evaluate the response of retinal vasculature as the dynamic vessel analyzer dva. Carl zeiss meditec, a video camera, a realtime monitor and a computer with vessel diameter analysis software. The rva imedos gmbh is a commercially available tool for the assessment of retinal vessel diameter in relation to time. Vessel analysis was developed by imedos in cooperation with universities and is based on proprietary technologies. Evaluation of the zeiss retinal vessel analyser kaija polak, guido dorner, barbara kiss, elzbieta polska, oliver findl, georg rainer, hansgeorg eichler, leopold schmetterer abstract aimto investigate the reproducibility and sensitivity of the zeiss retinal vessel analyser, a new method for the online determination of retinal vessel diameters. The retinal vessel analyzer rva is a measuring device for online measurement of the diameter of retinal vessels in relation to time and locations along the vessel. Imedos, jena, germany comprises a fundus camera ff 450.
Impact of intravitreal ranibizumab on vessel functionality. In combination with stimulation and provocation methods for retinal microcirculation and the geometrical resolution the function of vessels in a defined section can be assessed for the first time. Use of the retinal vessel analyzer in ocular blood flow. For many years in the area of human medicine instruments from imedos rva, sva, dva are used successfully in practice and research. A mydriatic fundus camera records a video sequence of the retina. Vilser1,2 1imedos gmbh, weimar, germany 2technical university of ilmenau, ilmenau, germany b. All patients were evaluated through optical coherence tomography and dynamic and static retinal vessel analysis, using the dynamic vessel analyzer imedos, jena, germany before administration baseline and 1 week, 1 month, and 2 months after administration of intravitreal dexamethasone. New imedos setup in aging research another medical discipline now working with retinal vessel analysis in may 2018, an imedos dynamic vessel analyzer dva has been installed at the wellestablished reynolds oklahoma center on aging of the. We are glad to announce the development of our new fundus camera rcrodent a noncontact imaging source for the static and dynamic retinal vessel analysis has been completed.
Retinal vessel analysis is a new technique to assess behavior of large retinal vessels based on diameter measurements. Typical reading from the retinal vessel analyzer software. Retina continuous retinal vessel diameter measurements. Retinal vessel analysis, oxygen saturation and functional diagnostic of the autoregulation or dysregulation can be accessed by the new dynamic vessel analyzer dva 3. Imedos, the expert of retinal vessel analysis, is a developer and manufacturer of systems to determine biomarkers of retinal microcirculation. Retinal vessel analysis was performed successively in 14 of the study centers in the munich area between the year 2010 and 20. Imedos systems, germany was transferred from center to center for the examinations. Rva was conducted with an imedos dynamic retinal vessel analyzer imedos, jena, germany using a zeiss ff450 plus fundus camera carl zeiss meditec ag, jena, germany connected with two chargecoupled device cameras that provide digital images for a computerized vessel analysis software imedos, jena, germany. Missing correlation of retinal vessel diameter with high. Fundus photography and retinal vessel responses were assessed by rva, intraocular pressure by contact. The same technical equipment including a modified mobile dynamic retinal vessel analyzer dvalight.
Prediabetes and type 2 diabetes are associated with. Together with contact glass dynamometry the offer of retinal vascular functional diagnosis has been highly appreciated by my patients as being a look outside the box. A semiautomated computer tool for the analysis of retinal. Rva retinal vessel analyzer dva dynamic vessel analyzer sva. Dynamic retinal vessel response to flicker in agerelated macular degeneration patients before.
Imedos software analyzed the retinal artery diameter rad, retinal vein diameters rvd and arterioletovenule ratio avr of. Reliability of retinal vessel calibre measurements using a. Functional and morphological changes of the retinal. The system allows noninvasive online measurement of the diameter of retinal vessels without mydriasis. For each photograph, the calibers of retinal arterioles and venules passing through a zone between 0. We generated age and sexspecific nomograms in a diseasefree subpopulation of 890 participants for determining the central retinal arteriolar equivalent crae, the central retinal venular. Data was acquired using a manoeuvrable dynamic vessel analyzer imedos systems ug. Dynamic vessel analyzer dva system for dynamic vessel analysis functions dynamic vessel analysis to determine the dilatation capability with flicker light stimulation for examination. Imedos, jena, germany, have shown that, in diabetic subjects without signs of retinopathy, there is a reduction of the retinal vessels vasodilator capacity in response to flicker stimulation 21, 22. Laser cyclophotocoagulation enhances the regulative.
Retinal arterial and venous reaction to flicker stimulation was examined by dynamic vessel analyzer dvalight, imedos systems in all participants. For safety reasons, participants with an intraocular pressure exceeding. As described in detail below, this instrument is avail. Fundus photographs from 4309 participants of the gutenberg health study were assessed using the retinal vessel analyzer software imedos. The dynamic vessel analyzer dva, imedos systems ug, jena, germanyuse for research only is a modification of a high end fundus camera ff450, carl zeiss gmbh, jena, germany with tailored hardware and software modules, allowing static and dynamic retinal vessel analysis rva, imedos, jena, germany. Purpose to analyse static characteristics and dynamic functionality of retinal vessels in eyes with central serous chorioretinopathy cscr by means of dynamic vessel analyzer dva. It is furthermore provided with several tools for analyzing the measured data. Mona reva for retinal vessel analysis reva is your valuable software when you are investigating disease development and progression or when you are doing population health studies. Over the last 5 years these technologies have been applied in our rva research retinal vessel analyzer and have been used in many clinical trials around the world. Static vessel analysis the retinal vessel analyzer rva. It consists of a fundus camera and an advanced image processing unit. I was very relieved that imedos established the compatibility of the software for static vessel analysis on the new device. Retinal microcirculation and the arteriolar to venular ratio analysis was performed using the static retinal vessel analyzer svat, imedos systems ug, jena, germany. Retinal vessel reactivity was measured with the dynamic retinal vessel analyzer imedos gmbh, using a published protocol.
No other potential conflicts of interest relevant to this article were reported. Use of the retinal vessel analyzer in ocular blood flow research. In brief, retinal vessel diameters were measured using a semiautomated piece of software vesselmap 2, imedos, germany by a single observer os. Altered neurovascular coupling as measured by optical. The addon vesselmap2 offers a semiautomated measurement for arterial venous ratio of retinal vessels. The dva dynamic vessel analyzer, which has been designed especially for clinical routine examinations, combines the highgrade fundus imaging system, the robust functions of static vessel analysis and the futureproof software for dynamic vessel analysis. Data was acquired using a manoeuvrable dynamic vessel analyzer imedos systems ug, jena for examination of retinal vessel dimension and neurovascular coupling. The semiautomatic vesselmap 2 software imedos systems on the dva was used for static vessel analysis. Use of the retinal vessel analyzer in ocular blood. Ambulatory aortic stiffness is associated with narrow.
Retinal vessel regulation at high altitudes 1 ios press. For research application, imedos provides the rvaresearch retinal vessel analyzer, which comes with an exceptionally extensive range of extra functions. Rva workstation dynamic vessel analysis examinations of the functional ability of vessels at a high level of precision can be made with the retinal vessel analyzer rvaresearch. All patients underwent a complete ophthalmic evaluation, including optical coherence tomography and dynamic and static retinal vessel analysis, using the dynamic vessel analyzer imedos, jena, germany before baseline and 1 week and 1 month after. Impaired retinal vessel dilation predicts mortality in end.
The retinal vessel analyzer rva measures continuously on. Impact of intravitreal dexamethasone implant on vessel. It allows continuous and online measurement of the diameter of a segment of a retinal blood vessel with a temporal resolution of 25 readings. For research application, imedos provides the rvaresearch retinal vessel analyzer, which comes with an exceptionally extensive range of extra. Using the ff450 retinal camera carl zeiss gmbh, jena, germany, included in the dva system, a 50degree fundus photograph was acquired in each subject. Role of electrophysiology in the early diagnosis and. The vessel diameter of the selected vascular section is determined automatically. Comparisons of microvascular and macrovascular changes in. Retinal vessel diameters are shown as a function of time. Recent functional studies have tested the behavior of retinal vessels in response to stimuli and measured the changes in vascular diameter with the laser doppler flowmeter or the dynamic retinal vessel analyzer imedos, germany. Vesselmap 1 analyzer imedos systems, germany was used to quantify the change in retinal vessel diameter one disk diameter from the optic disk margin in 18 healthy subjects for. Jun 1 62009 5 10k summary imedos gmbhs static vessel analyzer 510k number. Recently, an automated, online approach of the pa of retinal vessel was made possible through computerized analysis of videorecordings of the fundus 4.
Retinal vascular caliber as a biomarker for diabetes. Imedos gmbh, jena, germany is a commercially available tool for the assessment of retinal vessel diameter in relation to time. Retinal microcirculation was imaged by a retinal vessel analyzer rva and a nonmidriatic camera topcontrcnv2000. Sdra patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Primary openangle glaucoma vs normaltension glaucoma. Retinal imaging systems enable inspection of the eye fundus and highresolution documentation of retinal and. Flicker lightinduced retinal vasodilation in diabetes and. Imedos is the maker and distributor of dynamic vessel analyzer used in this study and other devices for retinal vessel analysis. The retinal vessel analyzer rva, imedos systems ug, jena, germany is a system for retinal imaging, and static and dynamic vessel analysis in human eyes 5. Preliminary data on retinal vessel reactivity in patients after sah using dynamic vessel analyzer dva, imedos systems ug, jena, german suggest a characteristic role of nvc in neurological. Static vessel analysis with zeiss fundus camera ff 450plus mydriatic integrates all functions of highresolution digital fundus imaging. As a pioneer of retinal vascular analysis, imedos has been acti ve in the research and development for over 20 years and offers outstanding microvascular analysis for clinical application. Calibers of the 6 largest retinal arterioles and venules, from both eyes, passing through a zone between 0.